High brightness LCD 4.3” display touch-screen and user friendly interface
Complies with IEC 60601, high safety designation with dual CPUs Automatically identify size for syringe of 2, 3, 5, 10, 20, 30, 50/60 ml
Unique anti-reserve function on motor to prevent upstream DERS (drug error reduction system) available
Available wireless Wi-Fi networking and remote control system with infusion central station (optional)
TECHNICAL SPECIFICATIONS
Electric protection Type: Class I
Electric protection Level: Defibrillation proof type CF applied Part Protection against fluid ingress: IP34
Working principle: Stepper motor lead screw operation continuous Classification: Syringe pump with open system to use universal syringes brands Special features:Dynamic pressure, night mode, stand-by, screen lock, password protection, change rate during running, automatic calculation, memory of last infusion settings, automatic calculation of concentration.
Specification parameters
Display: 4.3” TFT color touch screen
Infusion mode: 7 modes available (ml/h, body weight, TIVA, loading dose, ramp up/down, sequence and relay mode)
Micro mode: 100 ml/h – 1200 ml/h, programmable
Infusion rate range: 0.01 – 1500 ml/h depending on syringe size with min. increment 0.01 ml/h
Compatible syringes: 2ml, 3ml, 5ml, 10ml, 20ml, 30ml , 50/60ml
System accuracy: ≥1ml/h, ±2%
Infusion rate: Syringe size 2/3ml: (0.01-50) ml/h; 5ml: (0.01-100) ml/h;
10ml: (0.01-200) ml/h; 20ml: (0.01-400) ml/h; 30ml: (0.01-600) ml/h; 50ml: (0.01-1500)ml/h
Bolus rate: Syringe size 2/3ml: (0.1-50) ml/h; 5ml: (0.1-100) ml/h; 10ml: (0.1-200) ml/h; 20ml: (0.1-400) ml/h; 30ml: (0.1-600) ml/h; 50ml: (0.1- 1500)ml/h
Purge rate: Syringe size 2/3ml: 50 ml/h; 5ml: 100 ml/h; 10ml: 200 ml/h;
20ml: 400 ml/h; 30ml: 600 ml/h; 50ml: 1500 ml/h
KVO rate: 0.01-5.00ml/h default value is 1 ml/h
Micro mode settings range: Syringe size 2/3ml: (0.1-50) ml/h; 5ml: (100- 100) ml/h; 10ml:(100-200) ml/h; 20ml: (100-400) ml/h; 30ml: (100-600) ml/h; 50ml: (100-1500) ml/h
Minimum flow rate increment: 0.01ml/h
Bolus: Manual bolus and programmable bolus, anti-bolus support
Bolus Volume: Syringe size 2/3ml: Minimum 0.1ml, max 2ml; 5ml: Minimum 0.1ml, max 5ml; 10ml: Minimum 0.1ml, max 10ml; 20ml: Minimum 0.1ml, max 20ml; 30ml: Minimum 0.1ml, max 30ml; 50ml: Minimum 0.1ml, max 50ml
VTBI: 0-9999ml, minimum step is 0.01ml
Total Volume Infused: 0.01-9999.99ml, minimum step is 0.01ml
Time Range: 1min-99hrs59min
Purge: 100-1500 ml/h depending on syringe size
Occlusion levels: 12 levels
History records: More than 5000 records
Other functions: Nurse call, RS232, data export
Interface: Mini USB
Dimensions: 394(W)*90(D)*123(H) mm
Weight: 1,7kg
Power Supply
AC power supply: 100-240V 50/60Hz Input power: 50VA
DC power supply: DC 15V lithium battery
Battery Specifications: Model: DC 203
Specification: 11.1V 2600mAh Charging time: 5h under OFF state
Working time: ≥12h (after completely charging the new battery, when the environment temperature is 25°C and flow rate is 5ml/h, the constantly working time)
Alarm
Alarm information: VTBI near end, Syringe near empty, VTBI infused, syringe empty, pressure high, battery nearly empty, battery empty, no battery inserted, no power supply, check syringe, reminder alarm, Standby time expired, KVO finished
Environment
Operating:temperature: 5-40° C
humidity: 20-90%, non-condensable
atmospheric pressure: 86-106kPa Transport & Storage: temperature: -20-60° C
humidity: 10-95%, non-condensable atmospheric pressure: 50-106kPa
Optionals
IrDA, WIFI, drop sensor, docking station and intravenous central station